Note to users. If you're seeing this message, it means that your browser cannot find this page's style/presentation instructions -- or possibly that you are using a browser that does not support current Web standards. Find out more about why this message is appearing, and what you can do to make your experience of our site the best it can be.

Site Tools

  • AAAS
  • Subscribe
  • Feedback

Site Search

Search Advanced

Science 9 September 1988:
Vol. 241. no. 4871, pp. 1352 - 1354
DOI: 10.1126/science.3413497

Articles

Science, Vol 241, Issue 4871, 1352-1354
Copyright © 1988 by American Association for the Advancement of Science


articles

Autologous red cell agglutination assay for HIV-1 antibodies: simplified test with whole blood

BE Kemp, DB Rylatt, PG Bundesen, RR Doherty, DA McPhee, D Stapleton, LE Cottis, K Wilson, MA John, JM Khan, and al. et

Department of Medicine, University of Melbourne, Repatriation General Hospital, Victoria, Australia.

An antibody detection procedure based on agglutination of autologous red cells has been developed for samples of whole blood. A nonagglutinating monoclonal antibody to human red blood cells conjugated to a synthetic peptide antigen (in this case residues 579 to 601 of the HIV-1 envelope precursor, Arg-Ile-Leu-Ala-Val-Glu-Arg-Tyr-Leu-Lys-Asp-Gln-Gln-Leu-Leu-Gly-Ile-Trp- Gly-Cys - Ser-Gly-Lys) permitted the detection of antibodies to the human immunodeficiency virus type 1 (HIV-1) in 10 microliters of whole blood within 2 minutes. Agglutination was specifically inhibited by addition of synthetic peptide antigen but not by unrelated peptides. The frequency of false positive results was 0.1% with HIV-1 seronegative blood donors (n = 874). The false negative results were approximately 1% (n = 81). The autologous red cell agglutination test is potentially suitable for simple, rapid, qualitative screening for antibodies to a variety of antigens of medical and veterinary diagnostic significance.


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES:
Whole-Blood Agglutination Assay for On-Site Detection of Human Immunodeficiency Virus Infection.
A. Gupta and V. K. Chaudhary (2003)
J. Clin. Microbiol. 41, 2814-2821
   Abstract »    Full Text »    PDF »
Endotoxin tests in patients with sepsis.
K.P. Ng, M. Bhanumathy, G.S.Y. Ong, B.H. Yong, N. Parasakthi, M.T. Koh, C.P. Siow, and J. Bosco (1995)
Innate Immunity 2, 387-393
   Abstract »    PDF »



ADVERTISEMENT
Click Me!

ADVERTISEMENT
Click Me!

To Advertise     Find Products


Science. ISSN 0036-8075 (print), 1095-9203 (online)