Note to users. If you're seeing this message, it means that your browser cannot find this page's style/presentation instructions -- or possibly that you are using a browser that does not support current Web standards. Find out more about why this message is appearing, and what you can do to make your experience of our site the best it can be.

Site Tools

  • AAAS
  • Subscribe
  • Feedback

Site Search

Search Advanced

Science 28 October 1988:
Vol. 242. no. 4878, pp. 562 - 564
DOI: 10.1126/science.3140381

Articles

Science, Vol 242, Issue 4878, 562-564
Copyright © 1988 by American Association for the Advancement of Science


articles

Subattomole amino acid analysis by capillary zone electrophoresis and laser-induced fluorescence

YF Cheng and NJ Dovichi

Department of Chemistry, University of Alberta, Edmonton, Canada.

Subattomole analysis of fluorescein isothiocyanate (FITC) derivatives of amino acids is accomplished by combining capillary zone electrophoresis for high-efficiency separation with laser-induced fluorescence for high-sensitivity detection. Concentration detection limits range from 5 x 10(-12) molar for alanine to 9 x 10(-11) molar for lysine, injected in the column; 9 x 10(-21) mole of alanine is contained within the approximately 1-nanoliter injection volume at the detection limit. The alanine detection limit corresponds to fewer than 6000 molecules injected onto the column and represents an improvement of four orders of magnitude in the state of the art for fluorescent detection of amino acids and an improvement of six orders of magnitude in the state of the art for the detection limit for isothiocyanate derivatives of amino acids.


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES:
Presidential Address to the Mineralogical Society of America, Salt Lake City, October 18, 2005: Mineral surfaces and the prebiotic selection and organization of biomolecules.
R. M. Hazen (2006)
American Mineralogist 91, 1715-1729
   Abstract »    Full Text »    PDF »
Fully Automated Two-dimensional Capillary Electrophoresis for High Sensitivity Protein Analysis.
D. A. Michels, S. Hu, R. M. Schoenherr, M. J. Eggertson, and N. J. Dovichi (2002)
Mol. Cell. Proteomics 1, 69-74
   Abstract »    Full Text »    PDF »
Structurally Related Peptide Agonist, Partial Agonist, and Antagonist Occupy a Similar Binding Pocket within the Cholecystokinin Receptor. RAPID ANALYSIS USING FLUORESCENT PHOTOAFFINITY LABELING PROBES AND CAPILLARY ELECTROPHORESIS.
M. Dong, X.-Q. Ding, D. I. Pinon, E. M. Hadac, R. P. Oda, J. P. Landers, and L. J. Miller (1999)
J. Biol. Chem. 274, 4778-4785
   Abstract »    Full Text »    PDF »
Inducible Repair of Thymine Glycol Detected by an Ultrasensitive Assay for DNA Damage.
X. C. Le, J. Z. Xing, J. Lee, S. A. Leadon, and M. Weinfeld (1998)
Science 280, 1066-1069
   Abstract »    Full Text »
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip.
D. J. Harrison, K. Fluri, K. Seiler, Z. Fan, C. S. Effenhauser, and A. Manz (1993)
Science 261, 895-897
   Abstract »    PDF »
Recent Developments in Analytical Chromatography.
M. V. Novotny and M. V. NOVOTNY (1989)
Science 246, 51-57
   Abstract »    PDF »
Microcolumn separations and the analysis of single cells.
R. Kennedy, M. Oates, B. Cooper, B Nickerson, and J. Jorgenson (1989)
Science 246, 57-63
   Abstract »    PDF »



To Advertise     Find Products


Science. ISSN 0036-8075 (print), 1095-9203 (online)